Product Application
This device can be configured by users to switch the power supply of various electrical equipment on and off. It is widely used for street lamps, lighting fixtures, advertising signs, production equipment, motors, water pumps and other loads. Customization service is available. Please contact our customer service if you have special requirements.
Product Parameters
| Device Model | HKYS-D8RC008B |
| Resolution | 0.01mA |
| Response Time | <4s |
| Indication Mode | LCD Chinese Display |
| Output Standard Signal | 8-channel relay output, RS485 bus (Modbus-RTU) & wireless LoRa signals |
| Working Mode | Real-time measuring, continuous operation |
| Working Temperature | -20℃ ~ +60℃ |
| Relative Humidity | ≤95% |
| Working Voltage | AC 220V 50Hz ±5% |
| Transmission Distance | 5000 meters |
| Power Consumption | <8W |
Product Characteristics
- Two-Way Feedback
- 485 Communication
- Plc Control
- Many Versions
- Wiring And Order Taking
- Flame Retardant Housing
- Adjustable Frequency
- Adjustable Speed
- Guarantee Of Genuine Goods
Product Advantages

Large Liquid Crystal Display
Various displays at a glance
Autonomous Regulation
- Adjustable frequency to prevent code bumping
- Adjustable speed to meet different needs


Self-locking/spotting mode of operation
- Free adjustment for each wayTap/self-locking operating mode Meet different control requirements
- Each circuit can be controlled independently Device switch Free control without restriction
Switching Input and Output Function
The device has 8 switching inputs and 8 switching outputs. After successful pairing, the switching outputs of the two paired devices follow the state of each other’s switching inputs. That is: If one device’s switching input channel 1 is closed, the other device’s switching output channel 1 is closed; if one device’s switching input channel 1 is disconnected, the other device’s switching output channel 1 is also disconnected.
| Serial No. | Functions | Remarks |
| 1 | Read switching input status | |
| 2 | Read switching output status | |
| 3 | Set switching output status open / close, close after a period of time | |
| 4 | Modbus-RTU communication address modification (effective in real time) | |
| 5 | Modify Modbus-RTU communication baud rate (in real time) | |
| 6 | Modify LoRa transmit frequency (Real-time effect) | |
| 7 | Modify LoRa receive frequency (Real-time effect) | |
| 8 | Add LoRa to be paired device ID (effective in real time) | |
| 9 | Clear LoRa pending pairing device ID (effective in real time) |
Common Faults & Troubleshooting
| Malfunction | Reason | Treatment |
| Data display abnormality | Unmatched | Calibrate the corresponding channel and re-pair the device |
| Abnormal communication | Parameter settings do not match | Adjust the parameters of the host computer and the device to be consistent |
| Not shown | Power supply mismatch | Specify the power supply parameters in the instruction manual |
When the control output is active (AC220V), cut off the power supply before tightening the terminals.
Warning: When the control output is active (AC380V), disconnect the power supply before tightening the terminals.
Warning: When the control output is active (DC9-30V), cut off the power supply before tightening the terminals.